TitleProduct

Gas Zirconia Oxygen Analyzer

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2021-07-25 18:55

  • Browse the number:

    130

Send an inquiries
+
Woshilong Instrument (Beijing)Co., Ltd
Contactaixin:

woshilong(Mr.)  

Email:

telephone:

+86-029-8861 0736

phone:

Arrea:

Beijing

Address:

No.9 Shuangyuan Rd, Shijingshan District hi-tech park, Beijing.

Website:

http://www.wslinstrument.com/ http://woshilong.xgzkdz.com/

+

Description

The gas zirconia oxygen analyzer is suitable for continuous monitoring of the oxygen content in the flue gas produced by combustion equipment such as boilers and heating furnaces during the combustion process. Meanwhile, the gas zirconia oxygen analyzer can quickly and accurately display, detect, and analyze online to achieve low-oxygen combustion control, achieve energy saving and reduce environmental pollution.



Application
The gas zirconia analyzers are widely used energy-consuming industries, such as:

★ Steel industry

★ Electronic power industry

★ Petrochemical industry

★ Pottery industry

★ Various combustion equipment: incinerators, small and middle boilers, etc.



Main Features
★ Easy Operation Easy to operate by functional key.
★ Easily replaceable zirconia element.
★ IP66 or IP67 enclosure.
★ Fast response.
★ Withstand the pressure of ±8KPa.


Specification

Items

Specifications

Oxygen concentration:

0.001~100 vol%

Output signal:

4~20mA DC (maximum load resistance 750Ω)

Setting range:

0~20.6 vol% (0~30% can be set)

Digital communications:

Support Modbus 232/485 and Ethernet (selectable)

Heating time:

Approx. 20 min.

Repeatability:

±0.5vol% maximum value of set range.

Zero drift:

1.5 vol% maximum value of set range (60 days)

Response time:

Response of 90% within 5 seconds. (Measured after gas is introduced from standard gas inlet and oxygen signal starts changing).

Power supply:

220±10%VAC

Installation:

Flange mounting

Limit output:

Provide settable upper and lower limit outputs (optional)

Temperature control accuracy:

0~700℃ (Floating temperature calculation)

Equipment system accuracy:

±1%F.S.

Digit display mode:

4 bit LED nixie tube display

Operation:

Menu button operation

Calibration operation:

Three parameters on-line calibration

Equipment power:

Approx. 10W (Excluding heating power)

Heating power:

50W (average), able to supply maximum 150W power output

Environmental conditions:

Ambient temperature 0~70℃, relative humidity ≤ 90%


Detector length:

180mm\400mm\600mm\800mm\1000mm\1200mm\1500mm (customizable)

(Note: Detector length is from the detector tip to flange)


http://www.wslinstrument.com/